Basic Info.
Connection Structure
FC-ST
Allowed Lateral Pressure
100(N/100mm)<1000(N/100mm)
Allowed Tensile Strength
1000N<10000N
Certification
RoHS, CE, ISO9001, VDE, CCC
Product Description
Fiber Colors
12 colors per EIA/TIA 598. Black ring banding used when more than 12 fibers per tube.
Standards
Typical Structure and Parameter of OPGW
ASTM B415 ASTM A240 ASTM B398
Some structures and characteristics of typical representative OPGW are shown in the below list, however, they do not represent the whole products of the company. If you have any requests, please contact local representative office or directly contact the company.
Central Optical Fiber SUS Tube Structure (Parts) |
| Structure:central optical fiber SUS tube structure with single stranded layer |
| Order Type Model | OPGW-1C1/36 (M48/R60-12) | OPGW-1C1/40 (M58/R72-16) |
Max. fiber count | 36 | 40 |
Tube size | φ3.2 mm | φ3.5mm |
Cable diameter | φ9.6 mm | φ10.5 mm |
Cross-section carry area | 48 mm2 | 58 mm2 |
Cable weight | 338 kg/km | 400 kg/km |
Rated Tensile Strength(RTS) | 59 kN | 71 kN |
DC resistance at 20ºC | 1.782 Ω/km | 1.490 Ω/km |
Short current capacity (40~200ºC) | 11 kA2·s | 16 kA2·s |
Linear expansion coefficient | 13.0×10-6/ºC | 13.0×10-6/ºC |
Young's modulus | 162.0 kN/mm2 | 162.0 kN/mm2 |
| Structure:central optical fiber SUS tube structure with double stranded layers |
| Order Type Model | OPGW-2C1/30 (M127/R78-137) | OPGW-2C1/40 (M163/R100-226) |
Max. fiber count | 30 | 40 |
Tube size | φ3.0 mm | φ3.4 mm |
Cable diameter | φ15.0 mm | φ17.0 mm |
Cross-section carry area | 127 mm2 | 163 mm2 |
Cable weight | 529 kg/km | 673 kg/km |
Rated Tensile Strength(RTS) | 77 kN | 99 kN |
DC resistance at 20ºC | 0.329 Ω/km | 0.255 Ω/km |
Short current capacity (40~200ºC) | 137 kA2·s | 226 kA2·s |
Linear expansion coefficient | 17.5×10-6/ºC | 17.5×10-6/ºC |
Young's modulus | 97.3 kN/mm2 | 97.3 kN/mm2 |
Typical Structure and Parameter of OPGW(L)
Some structures and characteristics of typical representative OPGW are shown in the below list, however, they do not represent the whole products of the company. If you have any requests, please contact local representative office or directly contact the company.
Central Optical Fiber Aluminum Clad SUS Tube Structure (Parts) |
| Structure:central optical fiber aluminum clad SUS tube structure with single stranded layer |
| Order Type Model | OPGW(L)-1S 12(M83/R99-38) | OPGW(L)-1S 30(M104/R125-60) |
Max. fiber count | 12 | 30 |
Tube size | φ4.0 mm | φ4.5 mm |
Cable diameter | φ12.0 mm | φ13.5 mm |
Cross-section carry area | 83 mm2 | 104 mm2 |
Cable weight | 539 kg/km | 673 kg/km |
Rated Tensile Strength(RTS) | 99 kN | 125 kN |
DC resistance at 20ºC | 0.899 Ω/km | 0.724 Ω/km |
Short current capacity (40~200ºC) | 38.4 kA2·s | 59.8 kA2·s |
Linear expansion coefficient | 13.4×10-6/ºC | 13.4×10-6/ºC |
Young's modulus | 153.1 kN/mm2 | 153.8 kN/mm2 |
| Structure:central optical fiber aluminum clad SUS tube structure with double stranded layers |
| Order Type Model | OPGW(L)-1S 12(M234/R292-282) | OPGW(L)-1S 30(M295/R370-448) |
Max. fiber count | 12 | 30 |
Tube size | φ4.0 mm | φ4.5 mm |
Cable diameter | φ20.0 mm | φ22.5 mm |
Cross-section carry area | 234 mm2 | 295 mm2 |
Cable weight | 1531 kg/km | 1930 kg/km |
Rated Tensile Strength(RTS) | 292 kN | 370 kN |
DC resistance at 20ºC | 0.350 Ω/km | 0.279 Ω/km |
Short current capacity (40~200ºC) | 282 kA2·s | 448 kA2·s |
Linear expansion coefficient | 13.1×10-6/ºC | 13.1×10-6/ºC |
Young's modulus | 158.8 kN/mm2 | 159.1 kN/mm2 |
Typical Structure and Parameter of OPGW
Some structures and characteristics of typical representative OPGW are shown in the below list, however, they do not represent the whole products of the company. If you have any requests, please contact local representative office or directly contact the company.
Stranded Optical Fiber SUS Tube Structure (Parts) |
| Structure:stranded optical fiber SUS tube structure with double stranded layers |
| Order Type Model | OPGW-2S1/30(M107/R66-97) | OPGW-2S1/36(M128/R79-139) |
Max. fiber count | 30 | 36 |
Tube size | φ2.7 mm | φ3.0 mm |
Cable diameter | φ13.85 mm | φ15.2 mm |
Cross-section carry area | 107 mm2 | 128 mm2 |
Cable weight | 450 kg/km | 535 kg/km |
Rated Tensile Strength(RTS) | 65.8 kN | 78.9 kN |
DC resistance at 20ºC | 0.389Ω/km | 0.327Ω/km |
Short current capacity (40~200ºC) | 97 kA2·s | 138 kA2·s |
Linear expansion coefficient | 17.4×10-6/ºC | 17.4×10-6/ºC |
Young's modulus | 97.6 kN/mm2 | 97.8 kN/mm2 |
| Structure:stranded optical fiber SUS tube structure with double stranded layers |
| Order Type Model | OPGW-2S1/30(M107/R133-57) | OPGW-2S1/36(M128/R159-81) |
Max. fiber count | 30 | 36 |
Tube size | φ2.7 mm | φ3.0 mm |
Cable diameter | φ13.85 mm | φ15.2 mm |
Cross-section carry area | 107 mm2 | 128 mm2 |
Cable weight | 727 kg/km | 865 kg/km |
Rated Tensile Strength(RTS) | 133 kN | 159 kN |
DC resistance at 20ºC | 0.803Ω/km | 0.673Ω/km |
Short current capacity (40~200ºC) | 57 kA2·s | 81 kA2·s |
Linear expansion coefficient | 13.0×10-6/ºC | 13.0×10-6/ºC |
Young's modulus | 162.0 kN/mm2 | 162.0 kN/mm2 |
Typical Structure and Parameter of OPGW
Some structures and characteristics of typical representative OPGW are shown in the below list, however, they do not represent the whole products of the company. If you have any requests, please contact local representative office or directly contact Anhui Electric Group.
Stranded Optical Fiber SUS Tube Structure (Parts) |
| Structure:stranded optical fiber SUS tube structure with three stranded layers |
| Order Type Model | OPGW-3S1/36(M255/R116-590) |
Max. fiber count | 36 |
Tube size | φ3.0 mm |
Cable diameter | φ21.2 mm |
Cross-section carry area | 255 mm2 |
Cable weight | 879 kg/km |
Rated Tensile Strength(RTS) | 116 kN |
DC resistance at 20ºC | 0.145 Ω/km |
Short current capacity (40~200ºC) | 590 kA2·s |
Linear expansion coefficient | 19.6×10-6/ºC |
Young's modulus | 81.5 kN/mm2 |
| Structure:stranded optical fiber SUS tube structure with three stranded layers |
| Order Type Model | OPGW-3S1/48(M327/R407-530) |
Max. fiber count | 48 |
Tube size | φ3.4 mm |
Cable diameter | φ23.9 mm |
Cross-section carry area | 327 mm2 |
Cable weight | 2178 kg/km |
Rated Tensile Strength(RTS) | 406 kN |
DC resistance at 20ºC | 0.264 Ω/km |
Short current capacity (40~200ºC) | 530 kA2·s |
Linear expansion coefficient | 13.0×10-6/ºC |
Young's modulus | 162.0 kN/mm2 |
Hardware and Fittings for OPGW
The drawings below are shown with no detail size. If you have any requests, please contact local representative office or contact the company directly.
| |
Dead-end fitting(single) | Dead-end fitting(double) |
| |
Suspending clamp(single) | Suspending clamp(double) |
| |
Earth wire | Protection wire |
| |
Vibration damper | Joint-box |
| |
Wire clamp for tower | Wire clamp for pole |
OPGW CABLE & SYSTEM INFORMATION GUIDE FOR HARDWARE SELECTION
The following outline describes the OPGW cable information required to select proper cable attachment hardware and accessories. Most of the cable information can be found in the cable specification - it is recommended that this information be gathered along with the information about the cable system. Please submit this information to Anhui Electric Group to verify proper application.
Cable Information Required for Dead-Ends and Suspensions
CABLE SPECIFICATIONS/Cable Specification Sheet Data Cable Diameter: Overall outer diameter of the OPGW.Cable Construction Strand Configuration: Lay Direction of outer wire strands, Distribution and Location of individual strand materials in a cross-section, Number of strand layers.Rated Breaking StrengthFault Current
CABLE SYSTEMMaximum Vertical Load at Hardware AttachmentLine Angles
In addition to the outline above, other products offered for OPGW applications require further information as listed below:
Fiber Colors
12 colors per EIA/TIA 598. Black ring banding used when more than 12 fibers per tube.
StandardsAdditional Information for Other Hardware Accessories
Splice Closures, Closures, and Domes: Fiber CountFiber TypeFiber Optic Element ConfigurationType of Buffer Tubes (plastic or stainless steel)Core construction (Solid, Aluminum Tube, Aluminum Channel)
Spiral Vibration Damper: Span LengthsFinal Tension at the Average Annual Minimum Temperature (AAMT)Terrain
FITTINGS (Y-Clevis, Clevis Eye, Yoke Plates), Ground Wire, Downlead Cushions, Cable Storage: Interface at structureType of Structure (Wood Pole, Concrete, Steel, Lattice Tower)Ground Wire Material, Bonding Material
HARDWARE TESTS
The IEEE 1138 Test Standard for OPGW includes a series of tests that require suitable hardware to demonstrate system performance. System tests include Tensile Strength, Vibration Test, and Galloping Tests among others. System tests require dead-ends and suspensions that can survive the test parameters and prove cable/hardware compatibility.ASTM B415 ASTM A240 ASTM B398
Address:
No. 128, Tiancha Road, Economic Zone, Chuzhou, Anhui, China
Business Type:
Manufacturer/Factory, Trading Company, Group Corporation
Business Range:
Consumer Electronics, Electrical & Electronics, Industrial Equipment & Components, Instruments & Meters, Lights & Lighting, Manufacturing & Processing Machinery, Metallurgy, Mineral & Energy
Company Introduction:
China Anhui Electric Group Shares Co., Ltd. (CAHE) is a global company responsible for the production and distribution of wire and cable for the Energy Industry and to Electric Utilities responsible for power generation, transmission and distribution.
Our products include ABC Cable, ACSR, AAAC, AAC, ACSS, OPGW, Alumoweld, Galvanized Steel Wire, 15-35kV Copper and Aluminum Primary Distribution Power Cables, Secondary Aluminum and Copper 600V Service Drop and URD, 600V and 1kV Multi-conductor Control Cables, Bare Copper, Copper clad Steel, Industrial thermocouple, Industrial Thermal Resistance, Pressure Gauge Series, Bimetal thermometer, Paperless Recorder, Pressure transmitter, Temperature Transmitter, Intelligent Display Instrument, Level Meter / Flowmeter, Electrical equipment cable, Power cable, Bridge Series, Optical Fiber and Cable, Special cables, Special Thermocouple / Thermal Resistance and more.
CAHE makes it easier and less expensive as a complete solution for all cable needs. With inventory over $2 million in warehouses across P. R. China, we can solve immediate needs. Combined with our extensive manufacturing capability to ensure large project requirements, CAHE handles needs both large and small.
Our products are approved by CCC, AEIC, ICEA, ASTM, UL as applicable. (IEC, CSA, BS also available). CAHE is ISO 9001, 14001, 18000 certified.