LV, Copper or Aluminum, XLPE/PVC manufacturer / supplier in China, offering LV Cu/Al PVC/XLPE Insulated Unarmoured Power Cable, Marigold AAC All Aluminum Conductor ASTM B231, China IEC XLPE/PVC Insulated Computer Power Instrumentation Cables and so on.

(/ )

Supplier Homepage Product Power Cable LV Cu/Al PVC/XLPE Insulated Unarmoured Power Cable

LV Cu/Al PVC/XLPE Insulated Unarmoured Power Cable

FOB Price: Get Latest Price
Min. Order: 2,000 Meters
Port: Shanghai, China
Production Capacity: 500000m Per Month
Payment Terms: L/C, T/T, D/P, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: YJV
  • Voltage: Low and Medium Voltage Cable
  • Insulation Material: XLPE
  • Material Shape: Round Wire
  • Certification: ISO, CCC
  • Brand: Ae
  • Transport Package: Export
  • Origin: P. R. China
  • Application: Construction, Underground, Industrial, Power Station
  • Current: DC & AC
  • Sheath Material: Crosslinking
  • Wire Core Material: Bare Copper Wire
  • Model: YJV
  • Trademark: ae
  • Specification: YJV
  • HS Code: 8544492100
Product Description

LV Cu/AL XLPE /PVC insulated unarmoured power cable decsription:

Voltag:0.6-1KV
Conduntor: Copper/Aluminum 
Insulation:XLPE
Sheath:PVC, PE or LSZH
Standard:IEC 60502, BS 7870, GB/T12706
 LV Cu/Al PVC/XLPE insulated unarmoured Power Cable Application: 
It applies to electrical power transmission and distribution lines with AC rated voltage U0/U up to and including 0.6/1 kV. For outdoor and indoor installation in damp and wet locations, laid directly in the ground (when well protect in ducts, in trenches and in steel support brackets.)
 LV Cu/Al PVC/XLPE insulated unarmoured Power Cable Working:
1.The long time working temperature is at 90ºC, suffer short circuit (within 5 seconds), the temperature of core can not higher than 250ºC
2.The ambient temperature should not lower than -10ºC
3.The laying temperature should not lower than 0ºC
4.Single core's bend radius with no armor should not exceed 20D,single core's bend radius with armor should not exceed than 15D,three cores' bend radius with armor should not exceed 12Dith armor should not exceed 12Ds with a
rmor should not exceed 12D
LV Cu/Al PVC/XLPE insulated unarmoured Power Cable Parameter:
TypeNameApplication
CuAl
ConductorConductor
YJVYJLVXLPE Insulated,PVC or PE S heathed Power CableFor laying in door,tunnel,channel and underground.Unable to bear external mechanical force,but bear the traction force during laid.
YJYYJLV
VVVLVCopper/Aluminium core,PVC insulated,PVC sheathed power cableNon-armoured PVC cable are suited for laying indoors,In cable trench,On cable racks and in pipes. Unable bear external pressures and tensions.
VYVLYCopper/Aluminium core,PVC insulated,PE sheathed power cable
 
LV Cu/Al PVC/XLPE Insulated Unarmoured Power Cable
Cable sizeConductor typeNominal thickness of PVC insulation (mm)Nominal thickness of steel tape(mm)Nominal thickness of PVC sheath(mm)Approx. cable overall diameter (mm)Max. D.C resistance @ 200C (Ω/km)
4x1.5mm2RE or RM0.80.21.814.212.1
4x2.5mm2RE or RM0.80.21.815.17.41
4x4mm2RE or RM10.21.817.24.61
4x6mm2RE or RM10.21.818.53.08
4x10mm2RM10.21.821.61.83
4x16mm2RM10.21.824.11.15
4x25mm2SM1.20.21.823.80.727
4x35mm2SM1.20.21.825.90.524
4x50mm2SM1.40.5231.40.387
4x70mm2SM1.40.52.1350.268
4x95mm2SM1.60.52.339.90.193
4x120mm2SM1.60.52.443.10.153
4x150mm2SM1.80.52.647.30.124
4x185mm2SM20.52.852.30.0991
4x240mm2SM2.20.5358.40.0754
4x300mm2SM2.40.53.264.30.0601