Basic Info
  • Model NO.: YJV22
  • Voltage: High Voltage Cable
  • Insulation Material: XLPE
  • Material Shape: Round Wire
  • Certification: ISO, CCC, CE
  • Brand: Cahe
  • Transport Package: Drum
  • Origin: P. R. China
  • Application: Overhead, Power Station
  • Current: DC & AC
  • Sheath Material: PVC
  • Wire Core Material: Bare Copper Wire
  • Model: YJV
  • Trademark: CAHE
  • Specification: YJV
  • HS Code: 8544492100
Product Description

Steel Tape Armoured Cable

Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.

Prpperty:

1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.

Specification:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.

1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable


 No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

6.0

2.5

0.1

1.2

0.2

1.9

37.9

1.87

2.32

3 X 35

6.9

2.5

0.1

1.3

0.5

2.0

41.5

2.10

2.73

3 X50

8.2

2.5

0.1

1.3

0.5

2.0

44.3

2.37

3.22

3 X 70

9.7

2.5

0.1

1.4

0.5

2.1

47.9

2.77

4.00

3 X 95

11.3

2.5

0.1

1.4

0.5

2.2

51.6

3.21

4.91

3 X 120

12.8

2.5

0.1

1.5

0.5

2.4

55.4

3.69

5.84

3 X 150

14.2

2.5

0.1

1.5

0.5

2.5

58.6

4.15

6.85

3 X 185

15.9

2.5

0.1

1.5

0.5

2.6

62.5

4.73

8.11

3 X 240

18.3

2.6

0.1

1.6

0.5

2.7

68.5

5.62

10.05

3 X 300

20.4

2.8

0.1

1.7

0.5

2.9

74.5

6.55

12.11

3 X 400

23.2

3.0

0.1

1.9

0.8

3.2

83.6

8.78

15.86

3 X 500

26.4

3.2

0.1

2.1

0.8

3.4

93.0

10.52

18.85


2)6/10(12)kV,6.35/11(12)kV,,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

6.0

3.4

0.1

1.3

0.5

2.0

43.4

2.16

2.61

3 X 35

6.9

3.4

0.1

1.3

0.5

2.0

45.4

2.36

2.99

3 X50

8.2

3.4

0.1

1.4

0.5

2.2

48.8

2.69

3.54

3 X 70

9.7

3.4

0.1

1.5

0.5

2.3

52.4

3.10

4.33

3 X 95

11.3

3.4

0.1

1.5

0.5

2.4

56.1

3.56

5.26

3 X 120

12.8

3.4

0.1

1.5

0.5

2.5

59.5

4.04

6.19

3 X 150

14.2

3.4

0.1

1.5

0.5

2.6

62.7

4.49

7.19

3 X 185

15.9

3.4

0.1

1.6

0.5

2.6

66.6

5.12

8.49

3 X 240

18.3

3.4

0.1

1.7

0.5

2.8

72.4

5.99

10.42

3 X 300

20.4

3.4

0.1

1.8

0.5

3.0

77.5

6.86

12.42

3 X 400

23.2

3.4

0.1

1.9

0.8

3.2

85.4

8.97

16.05

3 X 500

26.4

3.4

0.1

2.0

0.8

3.4

93.7

10.65

19.50


3)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

6.0

4.5

0.1

1.4

0.5

2.1

48.6

2.53

2.98

3 X 35

6.9

4.5

0.1

1.4

0.5

2.2

50.7

2.76

3.39

3 X50

8.2

4.5

0.1

1.5

0.5

2.3

53.9

3.10

3.95

3 X 70

9.7

4.5

0.1

1.5

0.5

2.4

57.4

3.51

4.74

3 X 95

11.3

4.5

0.1

1.5

0.5

2.6

61.2

4.05

5.75

3 X 120

12.8

4.5

0.1

1.6

0.5

2.6

64.7

4.56

6.72

3 X 150

14.2

4.5

0.1

1.6

0.5

2.7

67.9

5.04

7.74

3 X 185

15.9

4.5

0.1

1.7

0.5

2.8

71.9

5.66

9.04

3 X 240

18.3

4.5

0.1

1.8

0.5

3.0

77.7

6.56

11.00

3 X 300

20.4

4.5

0.1

1.9

0.8

3.2

84.1

8.39

13.96

3 X 400

23.2

4.5

0.1

2.0

0.8

3.3

90.5

9.71

16.79

3 X 500

26.4

4.5

0.1

2.1

0.8

3.5

98.8

11.45

20.57


4)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

 

 

 

 

 

 

 

 

 

3 X 35

6.9

5.5

0.1

1.5

0.5

2.4

55.6

3.14

3.77

3 X50

8.2

5.5

0.1

1.5

0.5

2.5

58.6

3.49

4.34

3 X 70

9.7

5.5

0.1

1.5

0.5

2.6

62.1

3.93

5.16

3 X 95

11.3

5.5

0.1

1.6

0.5

2.6

65.7

4.46

6.16

3 X 120

12.8

5.5

0.1

1.7

0.5

2.7

69.4

5.00

7.15

3 X 150

14.2

5.5

0.1

1.7

0.5

2.8

72.6

5.49

8.19

3 X 185

15.9

5.5

0.1

1.8

0.5

3.0

76.9

6.16

9.53

3 X 240

18.3

5.5

0.1

1.9

0.8

3.2

83.9

7.87

12.31

3 X 300

20.4

5.5

0.1

2.0

0.8

3.2

88.6

8.96

14.52

3 X 400

23.2

5.5

0.1

2.1

0.8

3.5

95.4

10.35

17.43

3 X 500

26.4

5.5

0.1

2.2

0.8

3.7

103.7

12.45

20.23


5)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

 

 

 

 

 

 

 

 

 

3 X 35

 

 

 

 

 

 

 

 

 

3 X50

8.2

8.0

0.1

1.7

0.5

2.8

70.4

4.56

5.41

3 X 70

9.7

8.0

0.1

1.7

0.5

2.9

73.9

5.04

6.26

3 X 95

11.3

8.0

0.1

1.8

0.5

3.0

77.7

5.62

7.32

3 X 120

12.8

8.0

0.1

1.9

0.8

3.2

82.8

6.99

9.15

3 X 150

14.2

8.0

0.1

1.9

0.8

3.2

85.8

7.56

10.26

3 X 185

15.9

8.0

0.1

2.0

0.8

3.3

89.9

8.30

11.67

3 X 240

18.3

8.0

0.1

2.1

0.8

3.5

95.7

9.36

13.79

3 X 300

20.4

8.0

0.1

2.2

0.8

3.6

100.6

10.51

16.07

3 X 400

23.2

8.0

0.1

2.3

0.8

3.8

107.2

11.99

19.07

3 X 500

26.4

8.0

0.1

2.4

0.8

4.0

120.1

14.15

23.85

 

Main products:
Bare conductors(AAC,ACSR,AAAC,ACAR,Aluminum Clad Steel Conductor);

Aerial Bundled Cable (ABC Cable);

Power cable,Electrical wire cable,

Armored cables,

Control cables,

Rubber insulated cables, PVC insulated wires and cables,

Battery cables,Instrument cables, Coaxial cables,Flat cables,

Welding cables,House wire,Special Cables etc.

  

Why choose Us

1. Fast delivery 

2. Sample available .

3.Top cable supplier in China

4. ISO, IEC,CE ,CCC certifications.

5. Honest Manufacturer.

6.Advanced customization  

7.Strong technical support   

8.Strict quality control system 

9. Quality guarantee after delivery 
 

FAQ: 

1.Q: Is your company a manufacturer or a trade company?
A: We are cable manufacturer.

2. Q: Where is your factory located? How can I visit there? 
A:Our factory is located in Tianchang City, Anhui  Province, China. You can fly to Nanjing airport directly. All our clients, from home or abroad, are warmly welcome to visit us! 

3. Q: What is your sample policy?

A: Some of our samples are available for free, while others are available at a cost, which will be deducted from the purchase order.

4.Q: How does your factory do regarding quality control? 

A: Quality is priority. We always attach great importance to quality controlling from the very beginning to the very end.

5. Q: I am very interested in your product, can you sent me your full catalog and pricing list?

A: We can select some popular products for you immediately.  Please let us know your requirements so that we can send out the quotation to you.

Our Services

1. We guarantee to offer new advanced goods.

2. We'd like to send skilled personnel to the installing place to help offer technical consultant, quantity estimation and instruction, 

installing, preliminary testing,and help start up running; and to answer for any defect of the product found in installing and run testing,

If there's something wrong with the product, we'll give our answer within 12 hours and get to the spot within 36 hours.

3.After installaton, We'll send skilled personnel to have the preliminary test and answer for any problems emerged. We take the whole charge of the fee needed in repairing,testing or retesting within the scope of our duty required in contract.

4.During the contract's period of validity,of the project must be started all over again or the goods can not be used at all which is resulted from our faulty goods and improper files or mistakes made by our instructors, we'll change the goods at once without compensation and take charge in all expenses of reinstallation.

IEC60502 Steel Tape Armoured Power Cable

Send your message to this supplier
Avatar
Mr. James Wang
Manager
*From:
To: Mr. James Wang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now